Series C-06 & C-07: Quick Connect Power Transformers
2500-volt RMS Hipot, available in a variety of sizes. Insulation Class 130C. Available with
either single 115V, or dual 115/230V primary (for all but 2.4VA size). MCi's split bobbin and non-concentric
winding provide better insulation and high isolation, thus eliminating the need for electro-static shielding.
Adaptations of standard transformers are also available. Dots on schematics shown below indicate like
polarity.
Dimensions:
SIZE
|
VA
|
L
|
W
|
H
|
A
|
B
|
ML
|
LBS
|
3
|
2.4
|
2-1/16
|
1-1/16
|
1-3/16
|
1-7/16
|
9/16
|
1-3/4
|
0.25
|
4
|
6
|
2-3/8
|
1-1/4
|
1-3/8
|
1-11/16
|
11/16
|
2
|
0.44
|
5
|
12
|
2-13/16
|
1-3/8
|
1-5/8
|
1-15/16
|
13/16
|
2-3/8
|
0.70
|
6
|
30
|
3-1/4
|
1-11/16
|
1-15/16
|
2-5/16
|
1-1/16
|
2-13/16
|
1.10
|
7
|
56
|
3-11/16
|
1-13/16
|
2-1/4
|
2-11/16
|
1-1/16
|
3-1/8
|
1.70
|
8
|
100
|
4-1/32
|
2-1/4
|
2-9/16
|
3-1/16
|
1-5/16
|
3-9/16
|
2.75
|
|
Current Ratings (AMPS RMS):
Last 3 Digits of Part Number:
|
010
|
012
|
016
|
020
|
024
|
028
|
036
|
048
|
056
|
120
|
First 4 Digits:
|
|
Single 115V Primary
|
Dual 115/230 Primary
|
SERIES CONNECTION SECONDARY VOLTAGE
|
10V C.T.
|
12.6V C.T.
|
16V C.T.
|
20V C.T.
|
24V C.T.
|
28V C.T.
|
36V C.T.
|
48V C.T.
|
56V C.T.
|
120V C.T.
|
C-06-3-_ _ _
|
|
.250
|
.200
|
.150
|
.120
|
.100
|
.085
|
.065
|
.050
|
.045
|
.020
|
C-06-4-_ _ _
|
C-07-4-_ _ _
|
.600
|
.500
|
.400
|
.300
|
.250
|
.200
|
.170
|
.125
|
.110
|
.050
|
C-06-5-_ _ _
|
C-07-5-_ _ _
|
1.200
|
1.000
|
.800
|
.600
|
.500
|
.420
|
.350
|
.250
|
.220
|
.100
|
C-06-6-_ _ _
|
C-07-6-_ _ _
|
3.000
|
2.500
|
2.000
|
1.500
|
1.250
|
1.100
|
.850
|
.630
|
.540
|
.250
|
C-06-7-_ _ _
|
C-07-7-_ _ _
|
5.000
|
4.000
|
3.500
|
2.800
|
2.400
|
2.000
|
1.500
|
1.200
|
1.000
|
.500
|
C-06-8-_ _ _
|
C-07-8-_ _ _
|
10.000
|
8.000
|
6.250
|
5.000
|
4.000
|
3.600
|
2.800
|
2.000
|
1.800
|
.850
|
|
Part Number Designation:
- Locate the column, in the table above, for the required voltage.
- In the voltage column, locate the required current reading.
- Moving left from the current reading, find the number indicating required
primary - single 115V primary or dual 115V/230V.
- Derive part number by combining digits indentifying required primary and digits at the top
of column giving required voltage.

|