Series C-44: VDE PC Mount Transformers
4000-volt RMS Hipot, available in a variety of sizes. Insulation Class 130C. Available with
either 115V or dual 115/230V primary. MCi's split bobbin and non-concentric winding provide better
insulation and high isolation, thus eliminating the need for electro-static shielding. These transformers are designed
to pass VDE's strict creepage distance requirements.
Adaptations of standard transformers are also available. Dots on schematics shown below indicate like polarity.
Dimensions:
Transformer
|
VA
|
Schematic, Mounting Style
|
L
|
W
|
H
|
A
|
B
|
C
|
Pin Size
|
MW
|
ML
|
Screw Size
|
Max. No. Term- inals
|
LBS
|
C-44-3-_ _ _
|
2.5
|
1, A
|
1-5/8
|
1-7/16
|
1-1/8
|
.200
|
.250
|
1.000
|
.025 sq.
|
1-1/16
|
-
|
4
|
8
|
.25
|
C-44-4-_ _ _
|
5.0
|
1, A
|
1-5/8
|
1-7/16
|
1-3/8
|
.200
|
.400
|
1.000
|
.025 sq.
|
1-1/16
|
-
|
4
|
8
|
.37
|
C-44-5-_ _ _
|
10.0
|
1, A
|
1-7/8
|
1-9/16
|
1-3/8
|
.200
|
.400
|
1.140
|
.036 sq.
|
1-1/4
|
-
|
4
|
8
|
.53
|
C-44-6-_ _ _
|
20.0
|
2, A
|
2-1/4
|
1-7/8
|
1-5/8
|
.400
|
.400
|
1.460
|
.036 sq.
|
1-1/2
|
-
|
4
|
12
|
.90
|
C-44-7-_ _ _
|
30.0
|
2, B
|
2-5/8
|
2-3/16
|
1-9/16
|
.275
|
-
|
1.680
|
.045 sq.
|
1-3/4
|
2-3/16
|
6
|
12
|
1.15
|
C-44-8-_ _ _
|
56.0
|
2, B
|
3
|
2-1/2
|
1-13/16
|
.300
|
-
|
1.900
|
.045 sq.
|
2
|
2-1/2
|
6
|
12
|
1.70
|
|
Current Ratings (AMPS RMS):
Last 3 Digits of Part Number:
|
010
|
012
|
016
|
020
|
024
|
028
|
036
|
|
SERIES CONNECTION SECONDARY VOLTAGE
|
First 4 Digits:
|
10V C.T.
|
12.6V C.T.
|
16V C.T.
|
20V C.T.
|
24V C.T.
|
28V C.T.
|
36V C.T.
|
C-44-3-_ _ _
|
.25
|
.20
|
.15
|
.12
|
.10
|
.09
|
.07
|
C-44-4-_ _ _
|
.50
|
.40
|
.31
|
.25
|
.21
|
.18
|
.14
|
C-44-5-_ _ _
|
1.00
|
.80
|
.62
|
.50
|
.42
|
.36
|
.28
|
C-44-6-_ _ _
|
2.00
|
1.60
|
1.25
|
1.00
|
.83
|
.72
|
.56
|
C-44-7-_ _ _
|
3.00
|
2.40
|
1.90
|
1.50
|
1.25
|
1.06
|
.82
|
C-44-8-_ _ _
|
5.60
|
4.40
|
3.50
|
2.80
|
2.33
|
2.00
|
1.56
|
|
PARALLEL CONNECTION SECONDARY VOLTAGE
|
5V
|
6.3V
|
8V
|
10V
|
12V
|
14V
|
18V
|
C-44-3-_ _ _
|
.50
|
.40
|
.30
|
.24
|
.20
|
.18
|
.14
|
C-44-4-_ _ _
|
1.00
|
.80
|
.62
|
.50
|
.42
|
.36
|
.28
|
C-44-5-_ _ _
|
2.00
|
1.60
|
1.25
|
1.00
|
.84
|
.73
|
.56
|
C-44-6-_ _ _
|
4.00
|
3.20
|
2.50
|
2.00
|
1.66
|
1.44
|
1.12
|
C-44-7-_ _ _
|
6.00
|
4.80
|
3.80
|
3.00
|
2.50
|
2.12
|
1.64
|
C-44-8-_ _ _
|
11.20
|
8.80
|
7.00
|
5.60
|
4.66
|
4.00
|
3.12
|
|
Part Number Designation:
- Locate the column, in the table above, for the required voltage.
- In the voltage column, locate the required current reading.
- Moving left from the current reading, find the number indicating required
primary - dual 115V/230V.
- Derive part number by combining digits indentifying required primary and digits at the top
of column giving required voltage.

|